1000VA Online UPS Extended Runtime, ULT-W1KLHV
Capacity: 1000VA / 900W
Topology: Online double-conversion
Wave Form: Sine wave
Outlets: 3
Features:
• Sine wave output
• Microprocessor-controlled technology
• 0.9 power factor
• Wide input voltage range (120 - 300Vac)
• 1A to 6A adjustable charging current
• Expandable runtime
• Intelligent slot for an optional network card
• Frequency Converter Mode
• ECO Mode
The Ultima W series UPS delivers online power quality and scalable battery runtimes for servers, voice and data networks, storage systems and other IT equipment. Featuring Online Double Conversion design and Zero Transfer Time, it can provide consistent and seamless Pure Sinewave power to critical loads. With the add-on advantage of Extended Runtime battery packs, the UPS backup time can be extended to maximize workflow flexibility. An optional SNMP/HTTP Remote Management Capability enables remote management and control of the system through standard web browser. This series UPS cuts energy costs while significantly extending battery service life with ABM technology and it also has a bright LCD user interface to simplify monitoring.
Applications
Cost Effective Online UPS for Server Rooms, Telecom & Networking Applications, Surveillance & Security Systems, and Medical Applications.
OVERVIEW | ||
Model | ULT-W1KLHV | |
Capacity | 1000VA / 900W | |
Topology | Online double-conversion | |
INPUT | ||
Voltage | 208 / 220 / 230 / 240Vac | |
Voltage Range | 180 - 300Vac at full load; 120 - 300Vac at half load |
|
Frequency | 50 / 60Hz (auto-sensing) | |
Inlet | IEC C14 | |
OUTPUT | ||
Output Voltage | 208 / 220 / 230 / 240Vac | |
Frequency Range | 47 - 53Hz or 57 - 63Hz (synchronized range) | |
Frequency Range (on Battery) | 50Hz +/- 0.25Hz or 60Hz +/- 0.3Hz | |
Voltage Regulation (on Battery) | +/- 1% | |
THDv for Linear-Load | <3% | |
THDv for Non-Linear-Load | <6% | |
Crest Factor | 3:1 | |
Overload Threshold | Battery Mode: 105% - 110%: up to 10 minutes; 110% - 130%: up to 30 seconds; 130% - 150%: up to 3 seconds (Note: Temperatures above 35°C (95°F) will cause overload threshold duration to shorten.) |
|
Wave Form (on Battery) | Sine wave | |
Outlet | 3 x IEC C13 or 2 x Schuko | |
TRANSFER TIME | ||
Line To/From Battery | 0ms | |
Inverter To/From Bypass | 4ms (typical) | |
EFFICIENCY | ||
Line Mode | 88% | |
Battery Mode | 83% | |
BATTERY | ||
Chemistry | Sealed lead-acid | |
Quantity & Size | No internal batteries inside. External battery bank required for battery backup. | |
Recharge Time | Varies by charging current | |
Charging Current | 1 / 2 / 4 / 6A (adjustable) | |
Rated Battery Voltage | 27.4Vdc ± 1% | |
PROTECTION | ||
Overload Protection | Yes | |
Overcharge Protection | Yes | |
Surge Suppression | Yes | |
EMI / RFI Filter | Yes, full time | |
ADDITIONAL FEATURES | ||
Programmable Outlets | No | |
ECO Mode | Yes | |
External Battery Connector | Yes, maximum 6 external battery banks | |
Frequency Converter Mode | Yes, however if input is 60Hz, changing to 50Hz will derate UPS capacity by 40% | |
COMMUNICATION | ||
USB Port | Yes, for power management software to control and monitor the UPS conditions | |
RS232 Port | Yes, for power management software to control and monitor the UPS conditions | |
Software | Compatible with Windows 10/8/7/ Server 2012 R2 / 2008 R2 / Linux 32-Bit / 64-Bit / mac 10.6 to 10.11 | |
Intelligent Slot | Yes | |
STATUS INDICATORS | ||
LCD Screen | Yes, for Input/Output Voltages, Battery Level, Fault, and more | |
Audible Alert | Yes | |
WARRANTY | ||
Warranty | 2-year Equipment & Battery Warranties. See Terms of Use and Warranty pages for additional information. | |
ENVIRONMENT | ||
Installation Location | For indoor, temperature-controlled location free of contaminants only | |
Cooling | Forced air | |
Operating Temperature | 0°C up to +40°C / +32°F up to +104°F | |
Operating Humidity | 20% - 90% relative humidity | |
Noise | 50dB at 1 meter | |
PHYSICAL | ||
Color | Black | |
Form Factor | Tower | |
Product Dimensions (DWH) | 282 x145 x 220 mm / 11.10 x 5.71 x 8.66 in | |
Product Weight | 4.1 kg / 9.04 lb |
Product specifications are subject to change without further notice. Maruson assumes no responsibility, and disclaims all liability, for any damages that may result from the use of this information or for any errors or omissions. Battery backup time varies with equipment, configuration, battery age, temperature, etc. |
Brochure
Download here.
User Manual
Download here.
Software
Download here.
You must connect the USB from your UPS to your computer to use the software.
Compatible Operating Systems
Windows OS: Windows 10/ Windows 8/ Windows 7/ Windows Server 2016/ Windows Server 2012/ Windows Server 2012 R2/ Windows Server 2008/ Windows Server 2008 R2
mac OS: Mac OS 10.6/ 10.7/ 10.8/ 10.9/ 10.10/ 10.11
Linux 32-Bit and 64-Bit: Fedora 7/Redhat Enterprise 7.5/Centos 7/Open SUSE 11.4/Debian 7/Ubuntu 18.10
Virtual Machines (Agent and Client): VMware ESX/ESXi 6.5