1000VA Online UPS 4 Outlets, TAC-TW1K

In stock
SKU
TAC-TW1K
$480.00

 

 

Capacity: 1000VA / 900W
Topology: Online double-conversion
Wave Form: Sine wave
Outlets: 4

Features:
• Zero transfer time
• Sine wave output
• DSP technology
• Active PFC
• Wide input voltage range
• 1% output voltage regulation
• Intelligent slot for an optional network card
• Expandable runtime with add-on external battery banks

TUV logo

The Tacoma TW series takes business continuity to the next level. This advanced UPS system utilizes online double-conversion technology, ensuring the cleanest and most reliable power for your critical equipment. During outages or power fluctuations, the TW series seamlessly transitions to battery power, safeguarding your valuable equipment from data loss or damage. The built-in intelligent battery management system takes care of the details, optimizing battery charging and lifespan, and keeping you informed with timely replacement notifications. Additional features such as the flexibility to connect an external battery bank allow you to customize your power protection solution to perfectly match your specific needs. The Tacoma TW series represents the pinnacle of power protection innovation. Experience the peace of mind that comes with knowing your critical systems are protected by unparalleled precision and performance.

 

Typical Applications
Mid-size servers
ATMs
Lab equipment

Networking devices
Surveillance systems
VoIP / PBX systems

Security systems
Gaming computers
Slot machines

 

Main Features
(4) Battery-Backed Outlets
These outlets keep critical electronics online during a temporary blackout and offer protection from power surges and voltage spikes. If a blackout occurs or a power disruption beyond the tolerance range is detected, the UPS will switch over to battery power and supply these outlets with power.

True Double-Conversion Online Topology
The main supply is fed directly into the UPS and charges batteries within the UPS. The battery power is then converted back to the main power to feed the protected equipment. The isolation of input power from output power protects equipment from fluctuations, surges, and noise before reaching connected equipment delivers consistent, high-quality AC power.

Zero Transfer Time
True online double-conversion topology for seamless transition from Line Mode to Battery Mode in case of a power disturbance prevents malfunction of mission-critical equipment.

Pure Sine Wave Output
Sine wave output is the best wave form for equipment. It provides a stable, compatible, and clean power source, ensuring the proper functioning and longevity of sensitive electronic devices.

Benefits include:
• Smoother waveform
• Best for sensitive equipment
• Higher quality than a modified sine wave
• Maintains voltage at a safe level
• Motors run at their intended speed and with less heat
• Equipment runs with less noise
• IT equipment lasts longer
• Low harmonic distortion

DSP Controlled Technology
DSP (digital signal processor) controlled technology for high reliability, accuracy, and efficiency.

Active PFC to Improve Power Factor
Active PFC (power factor correction) improves the power factor and power quality of the UPS by reducing harmonic distortion on the electrical system to improve energy efficiency and reduce energy loss. Additional benefits include active wave shaping of input current, low voltage drop, filtering high frequency switching, waveform control through feedback sensing from the power source, and regulation of output voltage based on feedback control.

Wide Input Voltage Range
Minimizes the need to switch over to battery power and frequency of battery charge and recharge cycles by correcting extreme voltage distortion for higher system reliability and efficiency.

1% Output Voltage Regulation
The UPS regulates the output voltage to be within 1% of the set output voltage. Voltages outside acceptable ranges can cause electronics and electrical components to overheat and may cause premature failure of the devices.

The voltage reference of this UPS is set to a fixed 1% output voltage regulation even when parameters such as ambient temperature change. A precise output voltage is important for sensitive electronic equipment such as ones that require calibration for accuracy and also sensitive electronics are more susceptible to damage when receiving power outside its input range.

Emergency Power Off (EPO) / Remote On/Off (ROO)
Instantly shut off the UPS and prevent the UPS from supplying power such as in the event of an emergency for EPO, or system maintenance or shut-off for off-peak hours for ROO.

EMI / RFI Filter
EMI / RFI filter suppresses electromagnetic noise and radio frequency interference transmitted from AC power.

Smart Battery Management
Maximize battery performance and lifespan with an intelligent, multi-stage battery charging system to auto-sense the optimal battery charging performance based on battery capacity, temperature monitoring, battery health, and discharge control. The advanced battery monitoring system will also detect and send notification when the battery lifespan is near for timely battery replacement.

Overload Protection
Protects the UPS from an overload. If the circuit breaker trips, unplug a few electronics before resetting the circuit breaker and turning your unit back on.

Set Output Voltage and Frequency
Configure the output voltage to 100 / 110 / 120 / 125Vac and choose between 50Hz or 60Hz for optimal performance. This customizable feature ensures seamless compatibility and enhanced performance for sensitive electronics.

NOTE: Setting the UPS output to 50Hz (if input is set to 60Hz) will derate the UPS capacity by 40%. For this UPS, the capacity will be cut down to 540W maximum output capacity.

Extend Runtime Capacity
Select models offer scalable runtime through external battery banks. These models come equipped with connectors that allow you to connect up to 3 (Standard models) or 6 (Extended Runtime models) external battery packs, significantly extending your UPS's backup time during power outages.

Cold Start Capable
Turn on the UPS even without utility power as long as there is sufficient battery power.

Auto-Restart During AC Recovery
Once power returns to normal and the battery levels are sufficient, the UPS will automatically restart.

Off-Mode Charging
The UPS continues charging the internal batteries when powered off as long as the unit is plugged into an AC mains wall socket.

Power Management Software
Monitor and control the UPS from your computer with the included user-friendly software to automate computer shutdown, monitor battery levels, set UPS parameters, receive alerts of abnormalities, and more.

LED & LCD Status Indicators
See real-time status information of your UPS working conditions and power conditions including the voltages, battery capacity, fault, and other important information.

Mute Audible Alarm
Temporarily mute the audible alarm from your UPS when audible alerts are ongoing. The mute setting is reset once the UPS returns to a normal state for the next time unusual activity is detected.

Optional Accessories (Not Included)
• Network Management Card - For remote power monitoring. See model number #NMC for compatibility with this UPS series.
• Add-On External Battery Banks - Extend the battery runtime in the event of an extended power outage. See model # TAC-TW1KBB for compatibility with this UPS series. Maximum 3 x TAC-TW1BB may be used.

Warranty (US & Canada)
2-year limited equipment warranty, battery, and $25,000 connected equipment warranty with product registration. See Terms and Conditions and Warranty Policy pages for additional information.



WARNING: The batteries, battery posts, terminals, and related accessories can expose you to chemicals including lead and lead compounds, which are known to the State of California to cause cancer and birth defects, or other reproductive harm. Wash hands after handling. For more information, go to www.p65warnings.ca.gov.
OVERVIEW
Model TAC-TW1K
Capacity 1000VA / 900W
Topology Online double-conversion
INPUT
Voltage 100 / 110 / 120 / 125Vac
Voltage Range 100 - 145Vac at full load / 65 - 145Vac at half load
Frequency 50 / 60Hz (auto-sensing)
Inlet NEMA 5-15P
OUTPUT
Output Voltage 100 / 110 / 120 / 125Vac
Frequency Range Online Mode: 50 / 60Hz +/- 4Hz
Battery Mode: 50 / 60Hz +/- 1%
Voltage Regulation <1%
THDv for Linear-Load 4%
THDv for Non-Linear-Load 8%
Crest Factor 3:1
Wave Form (on Battery) Sine wave
Outlet 4 x NEMA 5-15R
TRANSFER TIME
Line To/From Battery 0ms
Inverter To/From Bypass <4ms
ECO to Battery <10ms
EFFICIENCY
Line Mode 88%
Battery Mode 85%
ECO Mode >95% at full load with batteries fully charged
BATTERY
Chemistry Sealed lead-acid
Quantity & Size 3 x 12V / 7Ah
Rated Charging Voltage 41Vdc
Recharge Time 5 hours to 90% capacity (internal batteries only)
PROTECTION
Emergency Power Off (EPO) Yes, EPO/ROO (Remote On/Off) connection
Overload Protection Yes
Overcharge Protection Yes
Surge Suppression Yes
EMI / RFI Filter Yes, full time
Network / Phone / Fax Surge Suppression No
ADDITIONAL FEATURES
Programmable Outlets No
ECO Mode Yes
External Battery Connector Yes, maximum 3 external battery banks (TAC-TW1BB)
COMMUNICATION
USB Port Yes, for power management software to control and monitor the UPS conditions
RS232 Port Yes, for power management software to control and monitor the UPS conditions
Software Compatible with Windows 10/8/7/ Server 2012 R2 / 2008 R2, Linux 32-Bit / 64-Bit / Sun Solaris / IBM Aix / Compaq True64 / SGIIRIX / FreeBSD / HP-UX / Mac OS X
Intelligent Slot Yes, requires add-on network card to use
STATUS INDICATORS
LED Status Indicator Indicates UPS mode
LCD Screen Yes, for Input/Output Voltages, Battery Level, Fault, and more
Audible Alert Yes
WARRANTY
Warranty 2-Year: Equipment, Battery, and $25,000 Connected Equipment Limited Warranties. See Terms of Use and Warranty pages for additional information.
ENVIRONMENT
Installation Location For indoor, temperature-controlled location free of contaminants only
Cooling Cooling fan
Operating Temperature 32°F to 104°F / 0°C to 40°C
Noise <50 dBA in Normal Mode
PHYSICAL
Color Black
Form Factor Tower
Product Dimensions (DWH) 13.74 x 5.67 x 8.82 in / 349 x 144 x 224 mm
Product Weight 25.79 lb / 11.7 kg

 

Product specifications are subject to change without further notice. Maruson assumes no responsibility, and disclaims all liability, for any damages that may result from the use of this information or for any errors or omissions. Battery backup time varies with equipment, configuration, battery age, temperature, etc.

Connect up to 3 external battery banks (EBBs) for extended runtime. Do not exceed 3 EBBs.

TAC-TW1K Runtime
115W 78 minutes   570W 11.5 minutes
225W 38 minutes   675W 8 minutes
335W 25.5 minutes   800W 6 minutes
450W 14.5 minutes   900W 4.5 minutes

 

TAC-TW1K Runtime + 1 EBB (9Ah x 6)Runtime
115W 282 minutes   570W 42 minutes
225W 136 minutes   675W 29 minutes
335W 90 minutes   800W 22 minutes
450W 53 minutes   900W 17 minutes

 

TAC-TW1K Runtime + 2 EBB (9Ah x 12) Runtime
115W 490 minutes   570W 72 minutes
225W 236 minutes   675W 50 minutes
335W 155 minutes   800W 38 minutes
450W 91 minutes   900W 29 minutes

 

TAC-TW1K Runtime + 3 EBB (9Ah x 18) Runtime
115W 702 minutes   570W 103 minutes
225W 338 minutes   675W 72 minutes
335W 221 minutes   800W 55 minutes
450W 131 minutes   900W 41 minutes

 


TIME (Minutes)
LOAD (WATTS)

Optional Add-On Accessories (not included)
NMC - Network management card for remote power management via web browser
TAC-TW1KBB - External battery bank for TAC-TW1K and TAC-TW1KL for additional battery runtime

Brochure
Download here.

User Manual
English - Download here.
Spanish / Español - Descarga aquí.

Software
Download here.

User serial number 511C1-01220-0100-478DF2A when prompted during installation. Note: You must connect the USB from your UPS to your computer to use the software.

Compatible Operating Systems
Windows OS: Windows 10/ 8 / 7 / vista / XP & Windows Server 2019 / 2016 / 2012 / 2008
mac OS: Mac OS 10.6/ 10.7/ 10.8/ 10.9/ 10.10/ 10.11
Linux 32-Bit and 64-Bit: Fedora 7/Redhat Enterprise 7.5/Centos 7/Open SUSE 11.4/Debian 7/Ubuntu 18.10
Virtual Machines (Agent and Client): VMware ESX/ESXi 6.5

No power to outlets
In Standby Mode, the outlets are not supplying power to connected equipment. Change the UPS from Standby Mode to Normal Mode for connected equipment to receive power by pressing the Power button while in Standby Mode for three seconds. The UPS will take approximately 15 seconds to complete startup diagnostics before switching to Normal Mode.


My serial number for the software does not work
The serial number to use the included software is printed in your user manual: 511C1-01220-0100-478DF2A. It is not the serial number of your UPS unit.


Does this model allow for external battery banks (EBB)?
Yes, this model accepts up to three (3) external battery banks to extend the battery runtime of your UPS when a power disturbance occurs.


Main differences between the different Tacoma TW models?

Variation Basic Standard Extended Runtime
Model TAC-TW1KB TAC-TW1K TAC-TW1KL
Internal Batteries 12V / 7Ah x 2 12V / 7Ah x 3 No internal batteries. Requires External Battery Bank (EBB).
Charging Current 1A 1A 4A
External Battery Bank Option No Yes, add up to 3 EBBs Yes, add up to 6 EBBs

LET'S CHAT

Not sure which model to purchase? Or, need help with a purchased item? Let us know how we can help.

PRODUCT REGISTRATION

Register your product for warranty coverage and expediated service requests.

WARRANTY

Find additional information on our warranty policy.