800VA Line-Interactive UPS 6 Outlets AVR Software, PRO-800LCD

In stock
SKU
PRO-800LCD
$119.99

 

 

Capacity: 800VA / 450W
Topology: Line-interactive
Wave Form: Simulated sine wave
Outlets: 6

Features:
• AVR for battery-backed outlets
• Surge suppression
• Auto restart while AC is recovering
• Off-mode charging
• Power management software
• Phone / fax / network combo ports

TUV logo

The PowerPro is a solid line-interactive UPS with automatic voltage regulation (AVR) function to monitor and stabilize incoming voltage levels to ensure electronic devices are protected from voltage fluctuations, brief blackouts, transient surges, and data line noise – all of which can negatively impact businesses and individuals who depend on electronic devices for optimal operation at all times. The AVR function not only protects devices against voltage fluctuations, it also extends the lifespan and maintains optimal performance of connected devices by providing more stable, consistent power. Inconsistent and unreliable power could lead to loss of revenue and downtime from data loss, offline duration, reduced efficiency, malfunction of devices, or even permanent damage to electronic devices under extreme conditions. Rest assured knowing your electronics are protected from power disturbances and battery-backed in case a power issue does arise. Utilize the included software to monitor and control UPS settings and conditions from a computer, or check the LCD for real-time status information.

 

Typical Applications
Entry-level computers
Workstations
Gaming consoles

Home networking devices
Point-of-sale devices
Surveillance systems

Smart home devices
Security systems
VoIP / PBX systems

 

Main Features
(3) Battery-Backed Outlets with AVR Function and Surge Protection
These outlets keep critical electronics online during a temporary blackout, adjust minor voltage fluctuations, and offer protection from power surges and voltage spikes.

If a blackout occurs or a power disruption beyond the tolerance range is detected, the UPS will switch over to battery power and supply these outlets with power. Connect mission-critical electronics to these outlets.

(3) Surge-Protected Outlets
Connect non-critical equipment to these outlets to protect the equipment from power surges and voltage spikes.

Automatic Voltage Regulation (AVR)
Automatically boosts or bucks minor voltage irregularities instead of switching to battery backup mode. By regulating the output voltage rather than using the battery, the UPS prolongs the lifespan of your battery and protects connected equipment against spikes, surges, brownouts, minor overvoltages and under voltages, and temporary blackouts.

The more boosts and bucks there are, the wider the acceptable input voltage range is, which will decrease the need to switch to battery power, therefore prolonging the lifespan of your battery. This series offers two-step boost and one-step buck AVR functions.

Overload Protection
Protects the UPS from an overload. If the circuit breaker trips, unplug a few electronics before resetting the circuit breaker and turning your unit back on.

Smart Battery Management
Maximize battery performance and lifespan with an intelligent, multi-stage battery charging system to auto-sense the optimal battery charging performance based on battery levels.

Power Management Software
Monitor and control the UPS from your computer with the included user-friendly software to automate computer shutdown, monitor battery levels, set UPS parameters, receive alerts of abnormalities, and more.

Phone / Network / Fax Line Suppression (RJ-11/45 Ports)
Protects telephone, network, or fax lines from line surges. Connect one line into the jack from the source and one line from the out jack to your phone, network, or fax line.

Cold Start Capable
Turn on the UPS even without utility power as long as there is sufficient battery power.

Auto-Restart During AC Recovery
Once power returns to normal and the battery levels are sufficient, the UPS will automatically restart.

Off-Mode Charging
The UPS continues charging the internal batteries when powered off as long as the unit is plugged into an AC mains wall socket.

LCD Screen
See real-time status information of your UPS power conditions including the voltages, battery level, fault detected, and more.

Enable / Disable Audible Alarm
Enable or disable the audible alert for your unit.

To enable or disable the audible alarm, turn the LCD screen on first then press the button twice quickly. The UPS will beep once the alarm is enabled. The default setting for the audible alarm is enabled. If the alarm is disabled, no audible alert will be made when the UPS reaches a low battery state.

Warranty (US & Canada)
3-year equipment warranty, 2-year battery warranty, and 3-year $25,000 connected equipment warranty with product registration. See the Warranty page for additional information.



WARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene (ABS) which are known to the State of California to cause cancer and birth defects or other reproductive harm. The battery in this product can exposure you to chemicals including lead and lead compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.p65warnings.ca.gov.
OVERVIEW
Model PRO-800LCD
Capacity 800VA / 450W
Topology Line-interactive
INPUT
Voltage 110 - 120Vac
Voltage Range 82 - 148Vac
Frequency 50 / 60Hz (auto-sensing)
Inlet NEMA 5-15P; straight plug
OUTPUT
Output Voltage 110 - 120Vac
Frequency Range (on Battery) 50 /60Hz +/- 1%
Transfer Time 4ms (typical)
Automatic Voltage Regulation Yes, 2-step boost and 1-step buck
Wave Form (on Battery) Simulated sine wave
Outlet 6 x NEMA 5-15R outlets (3 x battery-backed with AVR & surge protection; 3 x surge-only)
BATTERY
Chemistry Sealed lead-acid
Quantity & Size 1 x 12V / 7.2Ah
Backup Time @ 60W 48 minutes
Charging Current 1A
Recharge Time 4 hours to 90% capacity
PROTECTION
Overload Protection Yes
Overcharge Protection Yes
Network / Phone / Fax Surge Suppression Yes, RJ-11/45 combo ports (1-in, 1-out)
Surge Suppression Yes, 735 Joules
EMI / RFI Filter Yes, full time
COMMUNICATION
USB Port Yes, for power management software to control and monitor the UPS conditions
Software Compatible with Windows 10/8/7/ Server 2012 R2 / 2008 R2 / Linux 32-Bit / 64-Bit / mac 10.6 to 10.11
Intelligent Slot No
STATUS INDICATORS
LCD Screen Yes, for Input/Output Voltages, Battery Level, Fault, and more
Audible Alert Yes, to enable or disable the audible alert, press the power button to turn the LCD screen on, then press the power button twice quickly. Two short beeps mean the alert is now mute. One short beep means the alert is now audible.
WARRANTY
Warranty 3-Year: Equipment and $25,0000 Connected Equipment Warranties. 2-Year: Battery Warranty. See Terms of Use and Warranty pages for additional information.
PHYSICAL
Color Black
Form Factor Tower
Product Dimensions (DWH) 11.3 x 3.8 x 5.4 in / 286 x 96 x 138 mm
Product Weight 11.2 lb / 5.08 kg

 

Product specifications are subject to change without further notice. Maruson assumes no responsibility, and disclaims all liability, for any damages that may result from the use of this information or for any errors or omissions. Battery backup time varies with equipment, configuration, battery age, temperature, etc.
PRO-800LCD Runtime
10W 180 minutes   120W 22 minutes
30W 102 minutes   160W 16 minutes
60W 45 minutes   180W 10 minutes
90W 33 minutes   240W 5 minutes

 


TIME (Minutes)
LOAD (WATTS)

No additional accessories are available for this model.

Brochure
Download here.

User Manual
English - Download here.
Spanish / Español - Descarga aquí.

Software
Download here.

You must connect the USB from your UPS to your computer to use the software.

Compatible Operating Systems
Windows OS: Windows 10/ Windows 8/ Windows 7/ Windows Server 2016/ Windows Server 2012/ Windows Server 2012 R2/ Windows Server 2008/ Windows Server 2008 R2
mac OS: Mac OS 10.6/ 10.7/ 10.8/ 10.9/ 10.10/ 10.11
Linux 32-Bit and 64-Bit: Fedora 7/Redhat Enterprise 7.5/Centos 7/Open SUSE 11.4/Debian 7/Ubuntu 18.10
Virtual Machines (Agent and Client): VMware ESX/ESXi 6.5

Turning on the PowerPro Series
The Power Pro Series UPS has a two-step process to supply power to the battery-backed outlets. To turn these outlets on:
1. Press the power button for the LCD screen to illuminate. This illuminates the LCD screen if you ever need to see the UPS status.
2. While the LCD is still lit, press and hold the power button again until you hear a beep (approximately two seconds).

(If the LCD screen is already lit, simply press the power button for about two seconds until you hear a beep to turn on the UPS.)